Our site registration and log in will be unavailable from 8 p.m. CST on Friday, March 3 through 3 p.m. CST on Sunday, March 5. In addition to the usual gypsum found in regular drywall, fire-rated drywall contains glass fibers to form a super-tough core. It involves the use of nano engineered particles which are embedded in the polymer matrix of a Get free, zero-commitment quotes from pro contractors near you. New posts Search forums. View. By continuing to use and browse this site, you agree to our Privacy Policy. Quality is rated by the American Plywood Association (APA), which is accepted by most building codes, so look for the APA . Best Fire Resistant & Fire Retardant Paint (2023 Update) - The kitchen area happens to be the most fire-prone in your house. Double-Plywood (or Plywood), 2' X 10' Wood Joists 1-Hour - Exposed Grid L209 NA 24" x 48"; P 58" 16 113 1, 2 . Some common thicknesses include inch, 5/8 inch, and 3/4 inch. "telephone": "+1-888-990-3388", 19 mm thick ArchitectPly and Club Prime plywood enriched with Firewall technology performs superior under standard test condition to the benchmarks specified by Indian Standards IS 5509, American standards ASTM E84 and British standards BS 476 when measured against critical parameters like flammability, spread ability, penetration and smoke developed index. And it's not just thickness that makes the difference. The pressure is applied to help the chemicals infuse the wood fully and evenly for a length of time that is appropriate to the type, thickness, and amount of wood being treated. Add to basket. FLAME RETARDANT & FIRE RESISTANT COATINGS, 1-888-990-3388 Fire Rated. { supported by steel I beams/1 layer 1" wood plank, 1 layer 3/4" T&G wood, span 10", live load 40lbs, 3" x 10" F/D joists @ 16" o.c., w/ 1" x 4" T&G wood floor with tile over mortar base, span 10', live load 40lbs, 3" x 10" F/D joists @ 16" o.c., w/ 3 layers pf wood flooring, @ 1-1/2" thick, span 20'-25', live load 60lbs, 3" x 12" F/D joists @ 16" o.c., w/ 1 layer 3/4" T&G wood flooring, span 16', live load 40lbs, 3" x 14" F/D joists @ 20" o.c., w/ 3/4" T&G OSB flooring, w/ 5/8" T&G oak flooring, span 24'-6"', live load 40lbs, 2-3/4" x 13-3/4" Beams @ 15" o.c. Overview, Product/Safety Data sheets Related Products View All Structural Solutions LP TechShield Learn More LP NovaCore Learn More LP WeatherLogic Learn More LP Legacy Paint grade internal FD30 fire resistant door flush plywood door is a range of sizes with 35mm 44mm or 45mm thickness options. 30 Minute Fire Doors | Interior FD30 Fire Doors | Leader Doors CenturyPly enriched with Firewall technology is certified as the best in class by Indian , American and British standards when measured against critical parameters like flammability, spread ability, penetration and smoke developed index. We use cookies to provide a personalized site experience. Fire retardant plywood - FRT Plywood - Fire Resistant Treated Plywood Novato, Full Description Specification Delivery & Returns. Call us at (703) 972-1947 or contact us online today to get started. Fire Retardant MDF | FR Wood Panels | Hanson Plywood All Rights Reserved. Giving customers critical time to act, save lives, and call for emergency services. "url": "https://www.firefree.com", Log In. Another important measurement is flame spread, which is used to compare how rapidly a flame spreads on the surface of material versus other materials. system product alone constitutes a fire-rated assembly. When exposed to heat, an intumescent product expands or swells, which makes it act as a barrier and protect the substrate. Sometimes one product can meet multiple different levels of protection dependant on the substrate and how they are applied. J B Kind STP Flush Plywood Kintt6G Fire Door - 1/2 Hour Fire Rated - Wired Fire Glass . //18mm Russian Birch Plywood - Fire Retardant to Euro Class 'B' Type X or C drywall is 5/8 inches thick. These wall assembly files are used for planning and estimation purposes for many UL wall types, such as fire-rated wall assemblies. , w/3/4" T&G plywood, w/ 3" concrete, span 7', live load 40lbs, 2" x 13-1/2" joists @ 16" o.c., w/1 layer 1" wood plank & 1 layer 1" T&G wood, span 20", live load 100lbs, 2" x 12" F/D joists @ 12" o.c. Get each Blank for 237.73. w/1-1/8" T&G plywood floor, 1-1/2" gypcrete, span 31-34', live load 60lbs, 28" TJ''s (metal tubing) @24" o.c. , w/2 layers 1" " wood planking , live load 40lbs, 2"x 8" F/D joists @16" o.c. "e;}))++(y)^(iAtdeCoarchx.e(odrChamCro.fngriSt+=;o27=1y%2;*=)yy)0+12>((iif){" + This can give those inside the building more time to make their way outside to safety, and it also gives emergency crews more time to control the fire and rescue those who need assistance. We apologize for any inconvenience. - In critical situations, like a fire accident, the human mind usually starts panicking, and thus it becomes difficult to make practical decisions. It looks like you entered an employee email address, but this is the customer sign-in. "telephone": "+1-415-459-6488", sheets and other manuals, Wildfire System plywood giving them best in class fire-fighting properties. October 19, 2020 by Curtis Lumber & Plywood. Showing 1 - 36 of 297 products. span 18', live load 60lbs, 2" x 6" T&G wood planking, 2-1/2" x 12" F/D @16" o.c., 1 layer 3/4" T&G pine, span 12'-6", live load 40 lbs, 2" x 12" F/D @ 16-18" o.c., span 11', live load 40lbs, 1-1/4" T&G Pine & 1-1/4" wood planks, 11-7/8" TJ'I's @ 16" o.c. This is another common incorrect call-out by home inspectors. "contactType": "Customer Service" Another unfortunate effect of fire is death due asphyxiation caused by toxic gases and smoke emitted during a fire. 8 Commercial Blvd, Suite E We stock a wide range of Fire Retardant Panels, which include MDF, Chipboard, Plywood and OSB. To make it more heat-resistant and flame-retardant, builders use a special chemical treatment to make plywood fire-rated. 1 layer 5/8" type X gwb, 2" x 12" @24" o.c., 1/2" GWB, 1/2"plywood, 1 layer 5/8" GWB, 2" x 6" @24" o.c., 1/2" GWB, 1/2" RC channel, 1 layer 5/8" GWB, 2" x 10" Rafters @ 12" o.c., 1/2" plywood decking, 1 layer 5/8" type "X" gwb, 12" x 36" glulam beam., roof load 20lbs, 2" x 4" (1-1/2" wide) wood web trusses @24" o.c.,5/8" T&G plywood, R-30 fiberglass insulation, 1-1/2" x 25 gauge hat channel w 1 layer 1/2" sheet rock, 2" x 4" (1-1/2" wide) wood web trusses @ 24" o.c., 3/4" T&G OSB, 1 layer of 5/8" type "X" gwb, 2" x6" (1-1/2" wide) wood web trusses @ 24" o.c., 5/8" T&G plywood, 1 layer of 5/8" type "X" gwb, 2" X 4" (1-1/2" wide) wood web trusses @ 24" o.c., 19/32" OSB roof decking, 1-1/2" RC channel, 1 layer 5/8" type "X" gwb, 2" x 4" studs @16" o.c., w/ 1/2" GWB. It is essential to check your local laws and building codes to ensure that the wood you are choosing for your project will meet their requirements. if you put up a stud wall with one layer of normal plasterboard either side this gives you 30 minutes,, one layer of fireline on both sides of . X wood flooring, 1" x 3" wood spacers, embossed tin, 1-3/4" x 13-1/2" F/D @ 24"o.c., span 26', live load 40lbs, 3/4" T&G hardwood floor, 1" T&G pine ceiling, embossed tin. Type X has a denser core and contains glass fibers that keep it from crumbling in the heat. When this type of wood is exposed to a fire, it creates a non-combustible gas and water vapor to hinder combustion. the rate of fire growth, total heat release, smoke production and burning droplets are measured by testing samples of the products to EN 13823 (The SBI test) and . This numerical point of reference measures how quickly and far a flame will spread during a test that spans 10 minutes. With that said, the purpose of this plywood is to help prevent the spread of fire. FLAME PRO 3/4 Inch 4x8 Fire Retardant Plywood - The Home Depot Canada Fire safety experts agree its a great way to help make your home more fireproof. The air is then removed to create a vacuum into which the chemicals are added. The gained insulating char protects the elements composing the substrate from fire. This article is dedicated to helping you learn about this nifty plywood category. In addition to helping a building comply with applicable building codes, this material can also lower insurance costs. However, it is essential that fire-retardant plywood is protected from water and moisture throughout the storage and installation process to prevent the chemicals from leaching. Those will give you a good idea of what to expect. This makes it a safer type of wood to use in home structures and backboarding. }] Firefree Class A is a fire retardant coating fully tested to comply with building codes requirements and meet all ASTM E84 requirements, including the ASTM E84 30 Minutes Extended. From 348. Jeld-Wen Internal Flush Paint Grade Plus FD30 Fire Door 2040 x 44mm Retail price From 96.32 each From 80.27 ex. Up to 2135mm x 915mm x 44mm Up to 2440mm x 1220mm x 44mm 1981mm x 838mm x 44mm 2040mm x 826mm x 44mm 2040mm x 926mm x 44mm. The wood then undergoes a series of quality control checks to ensure that it is able to resist ignition and slow the spread of fire. Gyproc FireLine 12.5mm | Fire Resistant Plasterboard - British Gypsum It also allows more time for getting the fire under control and for those inside the building to escape. - Suffocation caused by smoke and other toxic gases emitted during fire accidents is a major problem. 2" x 4" web trusses 24" high, @24'O.C., span 17'-6", live load 40lbs, 3/4" Gypcrete Top layer 3/4" T&G plywood subfloor, 2" x 6 " web trusses 24" high @ 24" o.c., span 21'-6" live load @ floor 80lbs, 2 layers 3/4" plywood, 6" x 12" joists @ 16" o.c., span 10', 40lb live load, 3/4" osb subfloor, 2-1/2" x 6"joists F/D @ 16" o.c., span 7', live, load 50lbs, 8" x 8" F/D beam, 1" wood flooring, 2" x 8" F/D joists @ 24" o.c., 12' span, 3/4" wood flooring, live load 40lbs, 2" x 10" joists f/d@16" o.c., span 16', live load 40lbs, 1 layer 2" x 6" T&G, 1 layer hardwood flooring, 2" x 10" joists nominal @16" o.c., span 8', live load 40lbs, 1" gypsum plaster, 5/8" T&G plywood, 2" x 10" joists F/D @16"o.c., span 12', live load 40lbs, 2 layers 1" x 6" T&G Boards, 2" x 12" joists F/D @16" o.c., span 20', live load 40lbs, 1 layer 1" wood flooring, 1 layer finish laminate flooring, 2" x 12" joists f/d @16" o.c., span 8', live load 100 lbs, 2-1/2" wood decking, 2" x 12" joists 16" o.c, 3/4" osb., span 18', load 40lbs, 4" x 10" support beam, 4" x 4" support posts, 2-1/2" x 11-1/4" F/D joists @ 16"o.c., span 15', load 100 lbs, 2" thick wood boards, 2" x 14"joists F/D @ 16" o.c., span 20', live load 80lbs, 1-1/2" lightweight concrete, 3/4" T&G plywood, 3"x 12" joists f/d @ 12" o.c., span 10', live load 40 lbs, 1 layer 3/4" T&G wood, 1 layer 3/4" plywood, 3" x 12"joists F/D @ 16" o.c., span 17', live load 40 lbs, 1-1/4" T& G wood floor, 3" x 12" joists Nominal @ 12" o.c., 3/4" wood planking, span 18', live load 40lbs, acoustic panels, 3" x 14" joistsF/D @ 20" o.c., 5/8" T&G oak, 3/4" advantech OSB, 7/8" T&G decking, span 24'-6", live load 40lbs, 3" x 12" joists F/D @ 17" o.c.,1-1/2" x 8" Planking 11" x 14-1/2" support beams, 15" x 17" F/D @ 15'6" support columns, span 24'+, live load 40lbs, 3" x 12" joistsF/d @12" o.c., 3/4" (+/-) concrete, 1" solid wood, span 20', live load 40lbs, 3-1/2" x 9"joists F/D @16" o.c., 2 layers 3/4" T&G wood, span 5', live load 40lbs, 3" x 9" Glu-Lams @ 16" o.c. ICC-certified (ESR-1365) In areas like schools, hospitals, gymnasiums, and major retail stores, fire=rated plywood is used to help ensure that the structure is as safe as possible for people around the area. 2023 All rights reserved. Fire Retardant Plywood | Fire Resistant Plywood Price - CenturyPly , w/5/8" plywood, span 8', live load 20lbs, 2" x 6" rafters @24" o.c. . Description. CenturyPlys fire- retardant plywood, delays the spread of fire, giving you the much-needed time to rescue yourself and your loved ones. 020 3051 4794. This damage resistance makes pressure-treated plywood the best choice for exterior projects. Otherwise, you run the risk of having your home burn to the ground. Fire Rated Plywood, Fire Retardant, Fireproof Trade Plywood - Creffields "\\\\7503\\\\\\\\^JO]VT5[02\\\\\\\\0j01\\\\\\\\_QXF7D01\\\\\\\\14\\\\0q\\\\D" + Ossiana Tepfenhart is an expert writer, focusing on interior design and general home tips. In BS fire retardant properties is classified basis testing a plywood for its spread of flame at 90 sec and 10 min and basis the spread it is classified under Class 1, 2, 3 & 4. Fire-Rated OSB Sheathing | LP Building Solutions Interior fire-retardant plywood should never be used for exterior projects as it may not be able to stand up to the weather. These can include 30 and 60 minute fire resistance. *Please remember that plywood embedded with the Firewall Technology is fire-retardant and not fireproof plywood. But you might be struggling to figure out what kind of paint to use on garage walls. To find out what the minimum standards are for buildings in your area, make a point of looking at your local building codes. Fire-Rated Drywall: Is It Worth It? - This Old House //]]>, Firefree Coatings, Inc. w/80' span GLB, 6" x 14" @8'o.c. This technology comes at no additional cost to customers and can be found by contacting fire-retardant plywood suppliers in your area. FlameOFF Fire Barrier Paint has been tested to ASTM E119/UL 263 and ASTM E84/UL 723 Fire Endurance standards to meet the requirements set forth by IBC/NFPA Building Codes. Most cities will have certain statutes that give guidelines as to when fire-rated plywood should be used. FD30 Fire Doors | 30 Minute Fire Doors | Door Superstore "@context": "http://schema.org", Reaction usually relates to individual material components, such as timber and plywood, where they are sold with a known and measured reaction to fire. How to Make Plywood Into Fire Rated Plywood | eHow Plywood is not a fire-rated product. The board's excellent fire resistance rating makes it ideal for lining walls and ceilings in commercial spaces like offices and shopping centres, as well as in low rise housing and new build garages. w/ 4layers of wood flooring, total 2-1/2", span 23'-24', live load 40lbs, 3" x 14" joists @ 16" o.c., w/3/4" T&G plywood, 1-1/4" gypcrete, span 16', live load 40lbs, 7-1/4" x 13" joists @50" o.c., w/ 3" wood planking, 3" concrete supported on double 6" x 15" beams, span 17', live load 60lbs, 8" x 12" F/D joists @ 8' o.c., w/ 3" x 6" T&G wood floor, span 25', live load 40lbs, 2" X 4" web trusses @ 19'-2" o.c., w/3/4" T&G plywood, span engineered, live load 60lbs, 3" x 10" F/D @ 16" o.c., w/multiple layers of wood @ 2-1/4" thickness, span 9', live load 60lbs, 2" x 14" joists @ 16" o.c., w/ 2" x 4" diagonal bridging @ 8" o.c., span 25', live load 40lbs1 layer 1" diagonal wood sheathing, 2" x 14" F/D joists @ 16" o.c., span 11'-6", live load 40lbs, 1 layer 1" diagonal wood sheathing, 11-7/8 TJI's @ 16" o.c., live load 40 lbs, 3/4" T&G plywood, 7" x 13" @ 48" o.c., live load 40lbs, Beams Double 7-1/2" x 19", span 19'-3", 3" T&G wood plank, 2-1/4" x 13-1/2" wood@16" o.c., span 16', live load 60lbs, 2" wood decking, 2" x 11-1/2" f/d oak @12" o.c., span 18', live load 60lbs, 1" hardwood oak planking, 8" diameter beams @48" o.c. Fire-retardant Plywood substantially reduces this emission, thus preventing you from suffocation. For testing requirements, see Section 715.4.3. Below this, information from the woods quality tests appears, such as the flame spread and smoke-developed index (SDI) value, along with an ESR number or a statement of conformance to appropriate standards. 30 minute rated fire doors are the most common of the range and can be commonly used in homes as well as commercial premises. Fire Resistant Plywood at Lowes.com , w/3/4" T&G plywood, span 10'-14', live load 40lbs, 1-1/2"x 13" joists @16" o.c. "contactPoint": [{ Fire-rated plywood is available from general home improvement stores and lumber suppliers throughout the nation. While wood tends to burn faster, plastic tends to burn hotter. Firefree Coatings, Inc. Any thickness is allowed, but plywood is rated for various spans "for best performance." Look on the plywood sheets and they have a grade stamp, like 24/16. Coatings, Inc. Product/Safety Data Fire Retardant Paints for Wood & Timber | Rawlins Paints The smoke-developed number measures the concentration of smoke that wood emits when it is burned. High-Performance Fire Resistant and Flame Retardant Paint. The panels are 4 feet wide, minimum 7/16-inch thick oriented strand board (OSB) or 15/32-inch thick structural sheathing (plywood) complying with DOC PS1 or PS2, or APA Standard PRP-108, and manufactured with exterior glue. and which, when tested in accordance with UBC Standard 8-1 for a period of 30 minutes, shall have a flame spread of not over 25 and show no evidence of . Burning droplets/particles are measured for Reaction to Fire classes A2 to E. E-rated products receive a d2 flaming droplet classification. Flame Retardant Plywood Class C (30min) - SL Hardwoods Call: 1-800-USG-4YOU Contact Tech Support Moreover, the charring that occurs offers the wood an additional degree of protection from burning. Once the source of fire is removed it also acts to self-extinguish the fire. For example, the brand or product label appears above the name and location of the treating manufacturer so that buyers can check the reputations of the companies that made the wood. for a 19mm thick ply should be a minimum of 30 min. The label must also list the name and species of the product and the method that was used to dry it out. CLUB PRIME is made by a special pre-pressing technique that ensures equal distribution of moisture and adhesive. w/ 1/2" plywood roof decking live load 20lbs, 2" x 6" F/D joists @16" o.c. "e;}))++(y)^(iAtdeCoarchx.e(odrChamCro.fngriSt+=;o27=1y%2;*=)yy)0+12>((iif){" + "@type": "Organization", Fire-rated plywood is a type of wood that has been pressure-infused with fire-retardant chemicals, conferring it with permanent protection. 1-415-459-6488 Wood is also prone to igniting earlier than plastic, which is why most people tend to prefer plastic when it comes to areas that are prone to heat. Thank you! (BS476 Part 7). Have a Question About Assemblies? LPCB Approved ref: C022c. View our, New Products: USG Ceilings Inspirational Book, Danoline Acoustical Gypsum Inspirational Book, Acoustical Ceilings Performance Substrate, Ensemble Acoustical Drywall Ceiling Estimator, USG Acoustical Ceiling Panels & Acoustical Suspension Systems Catalog (WL294911), STRUCTO-CRETE Brand Structural Panels Portfolio, Levelrock & Durock Brand Fire & Sound Rating Guide, California Transparency in Supply Chain Act, Terms and Conditions for USG Sales/Terms and Conditions for USG POs. Deanta Internal Ash Fully Finished FD60 Fire Flush Door (54FLFDAX) From 270. Email: Yes. CenturyPly earnestly requests its customers to be completely and continuously vigilant against all common lapses that cause fire and in case of an unfortunate incident of fire, to immediately take all necessary steps like saving themselves, loved ones, recovering important assets and immediately engage fire engines, ambulances, doctors, electricity, gas authorities or any other authorities if required, to stop the fire. Email: Yes, plywood is allowed to protect the rigid insulation. Fire-rated plywood comes in a wide range of different hour ratings. Copyright Centuryply.com. Currently ArchitectPly and ClubPrime range of ply from April 21 will come with Firewall Technology. These guides will help you determine whether or not you want to use a particular type of fire-rated plywood. The other way to do it is to use a sealant or paint thats been rated for fireproofing. Fire resistant up to 60 minutes ( FD60) Solid core door blank. w/1-1/8" T&G plywood, 1-1/2" gypcrete, span 7' to 10', live load 60lbs, 11-7/8" TJ'I's @ 16" o.c. XL Joinery Novara Shaker 2 Panel Unfinished Oak Internal FD30 Fire Door - 1981mm x 762mm (78 inch x 30 inch) 247.50 incl VAT. The gypsum and fiberglass are packed tighter and denser than with regular drywall. This firewall technology allows a select range of CenturyPly plywood to be the most effective fire-fighting plywood available in India. Meeting fire codes just got easier - structural strength and code compliance in a single panel. Thus it is best prepared to fight against self disintegration due to fire, containing the spread of fire and smoke generation.This In turn helps rescue operations and gives customer critical time to act, save own and others lives, call for fire brigade, ambulance etc. Firefree 88 - Fire Resistant Assemblies for Wood, Gypsum, Plaster It also generates a lot of smoke. This paint is especially suitable for use on insulation board, MDF board, plasterboard, wood . Fire-rated doors are more common in commercial buildings than in residential structures. This includes things like ceilings, floors, and wall partitions for large-scale projects.